Panel One
Mode Templates
Apply preset climate values for quick review.
Switching mode updates the sliders immediately.
Panel Two
Outdoor Environment
Set outdoor air temperature and humidity.
Temperature
32°C
Relative Humidity
80%
Panel Three
Indoor Environment
Adjust air-conditioned indoor set points.
Temperature
24°C
Relative Humidity
50%
Panel Four
Panel Specification
Tune spandrel glass performance and insulation.
Spandrel Glass U-Value
2.8 W/m²K
Back-pan Insulation
50 mm
Panel Five
Risk & Visualization
Margin against dew point shown in the status band and chart.
Prediction Result
--
Adjust parameters to begin.
Calculating interpretation...
Disclaimer: This tool utilizes 1-Dimensional steady-state heat transfer equations (R-value method) and the Magnus formula for dew point calculation. It assumes continuous insulation and does not account for thermal bridging caused by aluminium mullions, transoms, or brackets. For critical architectural applications, a 2D Finite Element Analysis (THERM) is recommended.